Description
PREempt™ RTU One-Step Surface Cleaner&Disinfectant Solution by Virox
Application:
- Ideal for use on environmental surfaces in pharmaceutical and life science cleanrooms, labs, and other cGMP facilities (meets USP 797 requirements)
- Ideal for cleaning and disinfection of areas and surfaces including Secondary Engineering Controls (Ante Rooms and Buffer Zones) and Primary Engineering Controls (BSC, CACI, CAI, LAFS, LAFW, and RABS), work surfaces and other non-porous surfaces
- PREempt RTU has easy to use formats with no mixing or measuring required
- Designed for use as a daily cleaner and disinfectant; use at the beginning or end of each shift to clean counters and work surfaces
- Ideal for daily cleaning of floors in buffer area, ante-area, and segregated compounding area
Germicidal activity of this product was determined in accordance with the Canadian General Standards Board’s standard CAN/CGSB-2.161-97.
DISINFECTANT USE DIRECTIONS
Heavily soiled surfaces require cleaning prior to disinfection.
TO DISINFECT NON-CRITICAL, PRE-CLEANED INSTRUMENTS AND MEDICAL DEVICES:
1. Instruments must be thoroughly pre-cleaned to remove excess organic debris, rinsed, and dried.
2. Using either tray or an ultrasonic unit, immerse instrument in PREempt RTU for 3 minutes.
3. Wipe with a clean, damp cloth or paper towel and allow to air dry.
4. Discard solution after each use.
DISINFECTION OF NON-POROUS HARD SURFACES
- such as the exterior of fume hoods, tabletops and other environmental surfaces, etc. Apply to surface
with cloth or disposable wipe. Ensure surface remains wet for 3 minutes.
BROAD-SPECTRUM SANITIZING ON ENVIRONMENTAL SURFACES (>99.9%):
Apply to surface, allow to remain wet for 30 seconds. Wipe dry. No rinse required.
Food contact surfaces require rinsing with potable water.
CLEANING AND DISINFECTING SURFACES OF BLOOD AND BODY FLUIDS:
Gloves should be worn. Remove excess blood and fluid with absorbent
materials. Clean contaminated area: Apply to surface, allow surface to remain
wet for 30 seconds, wipe dry. Disinfect contaminated area: Apply to surface,
allow surface to remain wet for 3 minutes.
PERSONAL PROTECTION: Disposable gloves, gowns, facemasks, or eye
coverings as appropriate, must be worn during all cleaning of body fluids,
blood and decontamination procedures.
DISPOSAL OF INFECTIOUS MATERIAL: Products contaminated with blood
or body fluids should be disposed of according to Federal, Provincial, and local
regulations for infectious waste disposal.
Reviews
There are no reviews yet.